Testing and claims
Antibacterial is not an odour result
Ask for the tested specimen, method and care history. Keep wearer odour observations separate from that laboratory conclusion.
Keep the evidence identifiable
The record needs to identify claim wording, tested specimen and method and care history. For this collection, keep the following conditions beside those records.
| Evidence item | Application to this collection | Evidence status |
|---|---|---|
| Claim wording | Identified dry/damp condition and sample shade | Record the actual reference. |
| Tested specimen | Finished fabric and report specimen reference | Attach the specification and supporting evidence. |
| Method and care history | Material method record separate from wear notes | Retain the relevant sample or quotation. |
Evidence gap: what reopens approval
Match the proposed statement to liquid, drying, airflow or other relevant evidence. Keep method differences visible instead of deriving every claim from one result.
Before approving this application
Approve only supported, specific claim wording.
Buyer question
What closes the antibacterial claims decision for private label hot yoga apparel?
Keep claim wording, tested specimen and method and care history traceable to the actual proposal. The collection record is material method record separate from wear notes. Keep supporting documents with the approved sample before releasing production.
Sources and reporting scope
- AATCC official method directory
AATCC · Directory checked 23 November 2026 · checked 2026-11-23.
TM201 drying; TM204 water-vapour transmission; laundering methods. Public method titles establish scope. The laboratory must select the edition and conditions.
- AATCC TM195 liquid moisture-management scope
AATCC · Method edition to be recorded by the testing laboratory · checked 2026-11-23.
Public purpose and scope. Liquid moisture movement. Drying rate and air permeability need their own measurements.
- ASTM D737 air-permeability scope
ASTM International · D737-18(2023) public page · checked 2026-11-23.
Scope; significance and use. Report the test pressure, area, units and sample construction with results.
- LoYogas earlier guide: Antibacterial claims
Background for the original subject. The application above is adapted to this collection; no earlier author, publication date or completed test result is carried over.
Continue the sample decision
- Tight fit does not establish measured compression
- Ask which cooling property was measured
- Recovery observations need a stated material condition
Open the development brief · Measurement diagrams · Discuss this requirement